Furnace Crown Thermocouple

Furnace Crown Thermocouple

R Type Thermocouple

ParameterSpecification
MakeAavad
ModelARIS
ElementPt. Rh (13%)/Pt
Element diameter0.3 mm.
Calibration std.As per ANSI mc 96.1
ConfigurationSimplex
InsulationTwin hole ceramic Ker-610
Hot junctionUn-grounded
Terminal blockCeramic with nickel-plated brass terminals
HeadDie-cast aluminum weather-proof ANSI color-coded 'Blue' painted with threaded cover & chain
Protection class  IP-67
Cable entry1/2" (F) NPT
Holding tube mocSS 310
Holding tube diameter21 mm
Holding tube length150 mm
Ceramic tube length450 mm
No. of protectionSingle protection
Outer ceramic diameter15 X 10 mm. Id of ceramic Ker-610
JointsBetween holding tube & outer tube assembly by high temp. alumina compound bonding.
RangeUp to 1450°C


Please select a valid form

Description

  • Glass Melting Furnace includes a melting chamber in which solid batch materials are heated to produce molten glass. The arch of this melting chamber is known as crown. To measure and control the temperature of furnace crown is important, because with the correct temperatures one can improve the service life of crown, as the overheating of the crown may cause of early erosion of crown refractory and on the other side if the temperatures are low, it can affect the melting efficiency and will increase the fuel consumption. The highest temperature in melting furnace is at crown.

ARWS_21X450

Download